The analog EL3356 input terminal enables direct connection of a resistor bridge or load cell in a 4- or 6-wire connection technology. The ratio between the bridge voltage UD and the supply voltage UREF is determined simultaneously in the input circuit and the final load value is calculated as a process value on the basis of the settings in the terminal. With automatic self-calibration (can be deactivated) and dynamic filters the terminal with measuring cycles of 10 ms can be used for slow weighings with high precision.
| Technical data | EL3356 | ES3356 |
|---|---|
| Number of inputs | 2, for 1 resistor bridge |
| Power supply | via the E-bus |
| Technology | resistor bridge, strain gauge |
| Distributed clocks | – |
| Measuring range UD | max. -25…+25 mV rated voltage |
| Measuring range UREF | max. -12…+12 V rated voltage |
| Internal resistance | > 200 kΩ (UREF), > 1 MΩ (UD) |
| Input filter limit frequency | 10 kHz low pass (-3 dB) |
| Conversion rate | 100…4 samples/s (10…250 ms conversion time) |
| Power supply UV | up to 12 V from power contacts, dependent on sensor |
| Resolution | 16 bits, 32 bits presentation |
| Measuring error | < ±0,01 % for the calculated load value in relation to the final load value with a 12 V feed and 24 mV bridge voltage (hence nominal strain gauge characteristic value of 2 mV/V), self-calibration active, 50 Hz filter active |
| Current consumption power contacts | depends on strain gauge supply, min. 1 mA |
| Current consumption E-bus | typ. 210 mA |
| Supported nominal sensitivity | all, resolution of parameter: 0.01 µV/V recommended: 0.5…4 mV/V |
| Special features | auto-calibration, quadruple averager, dynamic filters |
| Weight | approx. 60 g |
| Operating/storage temperature | 0…+55 °C/-25…+85 °C |
| Relative humidity | 95 %, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. | IP 20/variable |
| Pluggable wiring | for all ESxxxx terminals |
![]() |
![]() |
| Related products | |
|---|---|
| EL3356-0010 | 1-channel precise load cell analysis (resistor bridge), 24 bit |
![]() |
![]() |